Sensors and Actuators B: Chemical 2018-03-23

Copper oxide-polyaniline nanofiber modified fluorine doped tin oxide (FTO) electrode as non-enzymatic glucose sensor

Ali Esmaeeli, Ali Ghaffarinejad, Alireza Zahedi, Omid Vahidi

Index: 10.1016/j.snb.2018.03.132

Full Text: HTML

Abstract

In this study, copper oxide-polyaniline nanofiber modified fluorine doped tin oxide (CuO/PANI-NF/FTO) electrode is introduced as a non-enzymatic glucose sensor. PANI-NFs were polymerized by a chemical method and through a cellulose ester membrane. These fibers were dip coated on FTO and then CuO particles were deposited on PANI-NFs by the electrodeposition method (CuO/PANI-NF). The morphology and structure were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS) and Fourier transform infrared (FTIR). The electrochemical response of the proposed electrode in presence of glucose was investigated in 0.1 M NaOH. In addition, comparing the performance of the CuO/PANI-NF/FTO with PANI-NF/FTO and the bare FTO indicated its superiority over the last two. The chronoamperometry (CA) linear range of the proposed sensor was between 0.25 μM to 4.6 mM with the detection limit of 0.24 μM (S/N = 3). The interference effect of some important species such as ascorbic acid, dopamine, uric acid, urea and sodium chloride was examined and no considerable interfering effect was observed. The repeatability and reproducibility of the electrode for glucose detection were 4.9 and 3.6%, respectively. Finally, the electrode stability was investigated and after 11 days, the electrode showed ∼90% of its initial signal. All results proved the proposed electrode excellence for non-enzymatic glucose sensing due to its simplicity, ease of preparation, wide linear range, appropriate selectivity and stability.

Latest Articles:

Sensitive and Selective Determination of Caspase-3 Based on Calixarene Functionalized Reduction of Graphene Oxide Assisted Signal Amplification

2018-04-11

[10.1016/j.snb.2018.03.185]

Using statistical methods to carry out in field calibrations of low cost air quality sensors

2018-04-11

[10.1016/j.snb.2018.04.021]

Self-powered smelling electronic-skin based on the piezo-gas-sensor matrix for real-time monitoring the mining environment

2018-04-10

[10.1016/j.snb.2018.04.046]

Naphthalene-Glycine Conjugate: An Extremely Selective Colorimetric Chemosensor for Iodide Ion in Aqueous Solution

2018-04-09

[10.1016/j.snb.2018.04.038]

A Novel Method for the Detection of Silver Ions with Carbon Dots: Excellent Selectivity, Fast Response, Low Detection Limit and Good Applicability

2018-04-09

[10.1016/j.snb.2018.04.036]

More Articles...