S J Asghar, G B Baker, G A Rauw, P H Silverstone
Index: J. Pharmacol. Toxicol. Methods 46(2) , 111-5, (2001)
Full Text: HTML
Acute administration of (+)-amphetamine has been used as a model for mania in humans since it mimics the physiological, biochemical, and cognitive effects seen in mania. A rapid and sensitive method for the determination of amphetamine in human plasma samples using gas chromatography with electron-capture detection was developed in our laboratory to follow the time course of amphetamine levels in patients receiving this drug as part of a study using amphetamine as a model for mania.Blood samples were taken from healthy male volunteers at 30, 60, 90, 150, 210, 240, and 480 min after administration of 25 mg of (+)-amphetamine. Plasma was isolated by centrifugation and used for the analysis. This method is a modification of the procedure described by Paetsch et al. [J. Chromatogr. 573 (1992) 313] for the determination of amphetamine in rat brain tissue. Amphetamine was derivatized under basic conditions using pentafluorobenzenesulfonyl chloride (PFBSC) prior to analysis on a gas chromatograph equipped with a capillary column and an electron-capture detector. The internal standard used was benzylamine. The structure of the amphetamine derivative was confirmed using combined gas chromatography-mass spectrometry (GC-MS).The limit of detection was <1 ng/ml, and the method was linear in the 1- to 100-ng range used. Mean amphetamine levels peaked at 3.5 h after drug administration, and were 40.8 +/- 1.5 ng/ml at that time.This procedure produces a stable derivative with excellent chromatographic properties and is both simple and reproducible.
Structure | Name/CAS No. | Molecular Formula | Articles |
---|---|---|---|
![]() |
Pentafluorobenzenesulfonyl chloride
CAS:832-53-1 |
C6ClF5O2S |
Simultaneous determination of fluoxetine and its metabolite ...
2002-04-05 [J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 769(2) , 305-11, (2002)] |
A rapid, sensitive electron-capture gas chromatographic proc...
2005-01-01 [J. Pharmacol. Toxicol. Methods 52(3) , 373-8, (2005)] |
Pentafluorobenzenesulfonyl chloride: a new electrophoric der...
1984-11-01 [Anal. Chem. 56(13) , 2512-7, (1984)] |
Electron-capture gas chromatographic analysis of beta-phenyl...
[J. Chromatogr. A. 381(2) , 211-7, (1986)] |
Pentafluorobenzenesulfonyl chloride as a sensitive reagent f...
1986-06-15 [Biochem. Pharmacol. 35(12) , 1925-8, (1986)] |
Home | MSDS/SDS Database Search | Journals | Product Classification | Biologically Active Compounds | Selling Leads | About Us | Disclaimer
Copyright © 2024 ChemSrc All Rights Reserved