B Jönsson, G Skarping
Index: J. Chromatogr. A. 572(1-2) , 117-31, (1991)
Full Text: HTML
A method for the determination of hexahydrophthalic acid, a metabolite of hexahydrophthalic anhydride, in human urine has been developed. The urine was worked-up by liquid-solid extraction, esterified with boron trifluoride-methanol, and analysed by capillary gas chromatography and selected-ion monitoring. Hexadeuterium-labelled hexahydrophthalic acid was used as the internal standard. The precision was 4% at 0.7 microgram/ml and 5% at 0.07 microgram/ml. The recovery of the acid for the overall method was 101% at 0.07 micrograms/ml of urine (with a coefficient of variation of 4%) and 95% at 0.7 microgram/ml (coefficient of variation 2%). The limit of detection was 20 ng/ml urine.
Structure | Name/CAS No. | Molecular Formula | Articles |
---|---|---|---|
![]() |
Lura
CAS:2305-32-0 |
C8H12O4 |
Determination of hexahydrophthalic acid and methylhexahydrop...
1997-04-11 [J. Chromatogr. B. Biomed. Sci. Appl. 691(2) , 331-9, (1997)] |
Toxicokinetics and biological monitoring in experimental exp...
1993-06-01 [Scand. J. Work. Environ. Health 19(3) , 183-90, (1993)] |
Generation of hexahydrophthalic anhydride atmospheres in a c...
1994-04-01 [Am. Ind. Hyg. Assoc. J. 55(4) , 330-8, (1994)] |
Occupational exposure to hexahydrophthalic anhydride: air an...
1993-01-01 [Int. Arch. Occup. Environ. Health 65(1) , 43-7, (1993)] |
Methods for the identification of chemical respiratory aller...
2003-01-01 [J. Appl. Toxicol. 23(4) , 199-207, (2003)] |