<Suppliers Price>

Tungsten carbide (WC)

Names

[ CAS No. ]:
12070-12-1

[ Name ]:
Tungsten carbide (WC)

[Synonym ]:
methanidylidynetungsten(1+)
Tungsten monocarbide Wolfram carbide
Tungsten carbide (WC)
Tungsten monocarbide,Wolfram carbide
EINECS 235-123-0
Tungsten Carbide
MFCD00011464

Chemical & Physical Properties

[ Density]:
15.63 g/cm3

[ Boiling Point ]:
6000ºC

[ Melting Point ]:
2870ºC

[ Molecular Formula ]:
CW

[ Molecular Weight ]:
195.851

[ Exact Mass ]:
195.950897

[ LogP ]:
0.08130

[ Water Solubility ]:
Soluble in nitric acid and hydrofluroic acid. Insoluble in water.

MSDS

Toxicological Information

CHEMICAL IDENTIFICATION

RTECS NUMBER :
YO7250000
CHEMICAL NAME :
Tungsten carbide
CAS REGISTRY NUMBER :
12070-12-1
LAST UPDATED :
199806
DATA ITEMS CITED :
21
MOLECULAR FORMULA :
C-W
MOLECULAR WEIGHT :
195.86
WISWESSER LINE NOTATION :
.WO..C

HEALTH HAZARD DATA

ACUTE TOXICITY DATA

MUTATION DATA

TYPE OF TEST :
DNA damage
TEST SYSTEM :
Human Leukocyte
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 392,31,1997 *** REVIEWS *** ACGIH TLV-TWA 5 mg(W)/m3; STEL 10 mg(W)/m3 DTLVS* The Threshold Limit Values (TLVs) and Biological Exposure Indices (BEIs) booklet issues by American Conference of Governmental Industrial Hygienists (ACGIH), Cincinnati, OH, 1996 Volume(issue)/page/year: TLV/BEI,1997 *** U.S. STANDARDS AND REGULATIONS *** MSHA STANDARD-air:TWA 5 mg(W)/m3 DTLVS* The Threshold Limit Values (TLVs) and Biological Exposure Indices (BEIs) booklet issues by American Conference of Governmental Industrial Hygienists (ACGIH), Cincinnati, OH, 1996 Volume(issue)/page/year: 3,272,1971 *** OCCUPATIONAL EXPOSURE LIMITS *** OEL-AUSTRALIA:TWA 5 mg(W)/m3;STEL 10 mg(W)/m3 JAN 1993 OEL-BELGIUM:TWA 5 mg(W)/m3;STEL 10 mg(W)/m3 JAN 1993 OEL-DENMARK:TWA 5 mg(W)/m3 JAN 1993 OEL-FINLAND:TWA 5 mg(W)/m3 JAN 1993 OEL-THE NETHERLANDS:TWA 5 mg(W)/m3 JAN 1993 OEL-THE PHILIPPINES:TWA 1 mg(W)/m3 JAN 1993 OEL-SWEDEN:TWA 5 mg(W)/m3 JAN 1993 OEL-SWITZERLAND:TWA 5 mg(W)/m3 JAN 1993 OEL-UNITED KINGDOM:TWA 5 mg(W)/m3;STEL 10 mg(W)/m3 JAN 1993 OEL IN BULGARIA, COLOMBIA, JORDAN, KOREA check ACGIH TLV OEL IN NEW ZEALAND, SINGAPORE, VIETNAM check ACGIH TLV *** NIOSH STANDARDS DEVELOPMENT AND SURVEILLANCE DATA *** NIOSH RECOMMENDED EXPOSURE LEVEL (REL) : NIOSH REL TO CEMENTED TUNGSTEN CARBIDE-air:10H TWA 0.1 mg(Co)/m3 REFERENCE : NIOSH* National Institute for Occupational Safety and Health, U.S. Dept. of Health, Education, and Welfare, Reports and Memoranda. Volume(issue)/page/year: DHHS #92-100,1992 NIOSH RECOMMENDED EXPOSURE LEVEL (REL) : NIOSH REL TO TUNGSTEN, insoluble-air:TWA 5 mg(W)/m3;STEL 10 mg/m3 REFERENCE : NIOSH* National Institute for Occupational Safety and Health, U.S. Dept. of Health, Education, and Welfare, Reports and Memoranda. Volume(issue)/page/year: DHHS #92-100,1992 NIOSH RECOMMENDED EXPOSURE LEVEL (REL) : NIOSH REL TO CEMENTED TUNGSTEN CARBIDE-air:10H TWA 0.015 mg/m3 REFERENCE : NIOSH* National Institute for Occupational Safety and Health, U.S. Dept. of Health, Education, and Welfare, Reports and Memoranda. Volume(issue)/page/year: DHHS #92-100,1992 NIOSH OCCUPATIONAL EXPOSURE SURVEY DATA : NOES - National Occupational Exposure Survey (1983) NOES Hazard Code - X2977 No. of Facilities: 158 (estimated) No. of Industries: 4 No. of Occupations: 7 No. of Employees: 3395 (estimated) No. of Female Employees: 297 (estimated)

Safety Information

[ Personal Protective Equipment ]:
Eyeshields;Gloves;type N95 (US);type P1 (EN143) respirator filter

[ Hazard Codes ]:
T

[ Risk Phrases ]:
R23

[ Safety Phrases ]:
22-24/25

[ RIDADR ]:
UN3178

[ WGK Germany ]:
-

[ RTECS ]:
YO7250000

[ Packaging Group ]:
III

[ Hazard Class ]:
4.1

Articles

Superficial roughness on composite surface, composite enamel and composite dentin junctions after different finishing and polishing procedures. Part I: roughness after treatments with tungsten carbide vs diamond burs.

Int. J. Esthet. Dent. 9(1) , 70-89, (2014)

The aim of this study is to investigate different instruments for finishing composite restorations, as well as examining different surfaces and interfaces of the same restoration. The null hypothesis ...

Comparison of microleakage of different margin types around Class V resin restorations in primary teeth.

Eur. J. Paediatr. Dent. 14(3) , 246-51, (2013)

This in vitro study compared the effect of a concave with a straight-bevelled cavity margin on the microleakage of Class V composite resin restorations in primary teeth.Standardised Class V cavity pre...

Qualitative and quantitative evaluation of enamel after various post-stripping polishing methods: an in vitro study.

Aust. Orthod. J. 28(2) , 240-4, (2012)

The purpose of this study was to evaluate the ultramorphology and surface roughness of permanent tooth enamel after various post-stripping polishing methods.Sixty extracted, permanent lower incisors w...


More Articles


Related Compounds